DocumentCode
403415
Title
An iron core probe based inter-laminar core fault detection technique for generator stator cores
Author
Lee, Sang Bin ; Kliman, G.B. ; Shah, Manoj R. ; Nair, Kutty ; Lusted, R. Mark
Author_Institution
Gen. Electr. Global Res. Center, Schenectady, NY, USA
Volume
3
fYear
2003
fDate
13-17 July 2003
Abstract
A new technique for detecting incipient interlaminar insulation failure of laminated stator cores of large generators is proposed in this paper. The proposed scheme is a low flux induction method that employs a novel probe for core testing. The new probe configuration, which uses magnetic material and is scanned in the wedge depression area, significantly improves the sensitivity of fault detection as well as user convenience compared to existing methods. Experimental results from various test generators tested in factory, field and lab environments under a number of fault conditions are presented to verify the sensitivity and reliability of the proposed scheme.
Keywords
cores; electric generators; fault location; iron; stators; electric machines; fault detection sensitivity; flux induction method; generator stator cores; incipient interlaminar insulation failure detection; interlaminar core fault detection; iron core probe; laminated stator cores; magnetic material; wedge depression area; Fault detection; Induction generators; Insulation; Iron; Magnetic cores; Magnetic materials; Probes; Production facilities; Stator cores; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Engineering Society General Meeting, 2003, IEEE
Print_ISBN
0-7803-7989-6
Type
conf
DOI
10.1109/PES.2003.1267447
Filename
1267447
Link To Document