DocumentCode
409075
Title
SNS linac commissioning - transverse matching
Author
Jeon, Dong-o ; Stovall, J.
Author_Institution
Oak Ridge Nat. Lab., TN, USA
Volume
4
fYear
2003
fDate
12-16 May 2003
Firstpage
2652
Abstract
The Spallation Neutron Source Linac consists of a few distinct sections which require careful transverse matching. Robust techniques for transversely matching various sections of the SNS Linac have been identified and presented. These techniques do not require us any knowledge of machine optics, and are robust against up to 20% measurement uncertainties, beam mismatch, etc.
Keywords
linear accelerators; particle beam diagnostics; particle beam dynamics; physics computing; proton accelerators; Coupled Cavity Linac; Drift-tube Linac; MATLAB; SNS linac; Superconducting Linac; beam mismatch; emittance measurement device; measurement uncertainties; rms beam size; transverse matching; wire-scanners; Linear particle accelerator; Mathematical model; Measurement uncertainty; Neutrons; Robustness; Search methods; Stimulated emission; Superconducting devices; Superconducting filaments and wires; Testing;