DocumentCode :
409179
Title :
Magnet-related failure experiences at the SPring-8 storage ring
Author :
Tsumaki, K. ; Kumagai, N. ; Matsui, S. ; Ohishi, M. ; Yonehara, H. ; Tateishi, T. ; Torii, Y.
Author_Institution :
SPring-8, Hyogo, Japan
Volume :
2
fYear :
2003
fDate :
12-16 May 2003
Firstpage :
884
Abstract :
High operation rate is required for synchrotron radiation sources for their many users. Keeping high operation rate, we need to maintain the equipments continually and raise the reliability of each component. To raise the reliability, it is important to clarify the cause of failure of equipments. In this paper, we describe the major magnet-related failure experiences of the past six years for the SPring-8 storage ring: failure of flow switch, dissolution of copper in water, and radiation damage of equipments.
Keywords :
electron accelerators; particle beam diagnostics; radiation effects; storage rings; synchrotron radiation; SPring-8 storage ring; equipment failure; flow switch; high operation rate; magnet-related failure experiences; radiation damage; synchrotron radiation sources; Coils; Cooling; Copper; Hoses; Magnetic switching; Maintenance; Rubber; Storage rings; Switches; Synchrotron radiation;