Title :
Vibrating wire and flipping coil magnetic measurement of a CESR-c 7-pole wiggler magnet
Author_Institution :
Laboratory of Nucl. Studies, Cornell Univ., Ithaca, NY, USA
Abstract :
To increase radiation damping at 1.8 GeV beam energy 12 super-conducting wiggler magnets will be installed in the Cornell Electron Storage Ring (CESR). The first 7-pole wiggler has been manufactured, tested and installed in the ring. This paper describes the wiggler magnetic measurement using flipping coil and vibrating wire techniques. The field integrals along straight lines were measured with flipping coil, vibrating wire technique was used to measure both, straight line field integrals and field integrals along wiggling lines reproducing beam trajectories.
Keywords :
accelerator magnets; particle beam diagnostics; particle beam dynamics; storage rings; superconducting magnets; wigglers; 1.8 GeV; CESR-c 7-pole wiggler magnet; Cornell Electron Storage Ring; beam energy; beam trajectories; flipping coil magnetic measurement technique; radiation damping; straight line field integrals; superconducting wiggler magnets; vibrating wire technique; wiggler magnetic measurement; Coils; Damping; Electron beams; Magnetic field measurement; Magnetic variables measurement; Manufacturing; Storage rings; Undulators; Vibration measurement; Wire;
Conference_Titel :
Particle Accelerator Conference, 2003. PAC 2003. Proceedings of the
Print_ISBN :
0-7803-7738-9
DOI :
10.1109/PAC.2003.1289593