DocumentCode :
409341
Title :
Calibration of RHIC electron detectors
Author :
He, P. ; Hseuh, H.C. ; Gassner, D. ; Gullotta, J. ; Trbojevic, D. ; Zhang, S.Y.
Author_Institution :
Collider-Accelerator Dept., Brookhaven Nat. Lab., Upton, NY, USA
Volume :
2
fYear :
2003
fDate :
12-16 May 2003
Firstpage :
1425
Abstract :
To characterize the electron cloud in RHIC, eleven custom electron detectors have been designed, fabricated and installed at a few RHIC warm-bore vacuum sectors for data collection during FY2003 runs. Prior to installation, the transmission and collection efficiencies of these detectors at various grid and collector bias voltages were measured using an electron gun with energy up to 1500 eV. This paper describes the design of the detector and the test system set-up, and summarizes the calibration results. In addition the calibration of a commercial microchannel plate is also reported.
Keywords :
beam handling techniques; electron accelerators; electron detection; electron guns; ion accelerators; particle beam diagnostics; particle beam dynamics; storage rings; synchrotrons; RHIC electron detectors; RHIC warm-bore vacuum sectors; bias voltages; commercial microchannel plate; electron cloud; electron gun; Boring; Calibration; Clouds; Detectors; Electrons; Energy measurement; Gold; Particle beams; Testing; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 2003. PAC 2003. Proceedings of the
ISSN :
1063-3928
Print_ISBN :
0-7803-7738-9
Type :
conf
DOI :
10.1109/PAC.2003.1289727
Filename :
1289727
Link To Document :
بازگشت