Abstract :
Leakage current through a printed circuit board epoxy has a strong Arrhenius dependence on temperature. Fire and smoke occurrences can be prevented by monitoring the leakage current between a ground plane and an adjacent test plane and shutting off power if the leakage current rises above a predetermined critical value.
Keywords :
leakage currents; power supplies to apparatus; printed circuit design; Arrhenius dependence; fire prevention; leakage current; power supplies; printed circuit board epoxy; smoke prevention; Circuit testing; Filters; Fires; Glass; Land surface temperature; Leakage current; Monitoring; Polymers; Power supplies; Printed circuits;