• DocumentCode
    415653
  • Title

    Failure analysis on resistive opens with Scanning SQUID Microscopy

  • Author

    Hsiung, S. ; Tan, K.V. ; Komrowski, A.J. ; Sullivan, D.J.D. ; Gaudestad, J. ; Orozco, A. ; Talanova, E. ; Knauss, L.A.

  • Author_Institution
    LSI Logic Corp., Fremont, CA, USA
  • fYear
    2004
  • fDate
    25-29 April 2004
  • Firstpage
    611
  • Lastpage
    612
  • Abstract
    Scanning Super-conducting Quantum Interference Device (SQUID) Microscopy, also known as SSM, is a current density imaging technique that has been used in failure analysis to localize package- and die-level shorts. New developments have extended this technology to localizing resistive opens, augmenting other non-destructive failure analysis tools like TDR and assisting destructive deprocessing by further pin pointing defect locations. A new method to isolate resistive opens with Scanning SQUID microscopy will be presented in this paper, and demonstrated on actual resistive open yield failures in both wire-bond and flip-chip devices.
  • Keywords
    SQUIDs; nondestructive testing; semiconductor device breakdown; semiconductor device reliability; semiconductor device testing; Scanning SQUID Microscopy; current density imaging technique; die-level shorts; failure analysis; flip-chip devices; localize package-level shorts; nondestructive failure analysis; resistive opens; wire-bond devices; Bonding; Current distribution; Failure analysis; Integrated circuit interconnections; Large scale integration; Magnetic fields; Microscopy; Packaging; SQUIDs; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Reliability Physics Symposium Proceedings, 2004. 42nd Annual. 2004 IEEE International
  • Print_ISBN
    0-7803-8315-X
  • Type

    conf

  • DOI
    10.1109/RELPHY.2004.1315414
  • Filename
    1315414