DocumentCode
416810
Title
Unsteady flow measurement using characteristics of closed cylindrical air chamber
Author
Inaoka, H. ; Shimizu, M. ; Ishida, A.
Author_Institution
Tokyo Med. & Dental Univ., Japan
Volume
3
fYear
2003
fDate
4-6 Aug. 2003
Firstpage
3070
Abstract
This paper deals with a method of unsteady flow measurement. This method utilizes a closed cylindrical air chamber installed in the pipeline. In this method, the volume change of the air chamber is calculated using the characteristics of the chamber. Good agreement was achieved between the measured and the calculated unsteady flow rate, and then the accuracy of this method was discussed.
Keywords
flow instability; flow measurement; pipe flow; pipelines; closed cylindrical air chamber; pipeline; unsteady flow measurement; unsteady flow rate;
fLanguage
English
Publisher
ieee
Conference_Titel
SICE 2003 Annual Conference
Conference_Location
Fukui, Japan
Print_ISBN
0-7803-8352-4
Type
conf
Filename
1323875
Link To Document