DocumentCode
416980
Title
Isotonic tension and isometric displacement measurement of a solid polymer electrolyte membrane-gold
Author
Ihara, Tadashi ; Nakamura, Tatsuki ; Nakamura, Taro ; Ikada, Yoshito ; Asaka, Kinji ; Fujiwara, Naoko ; Oguro, Keisuke
Author_Institution
Suzuka Univ. of Med. Sci., Japan
Volume
2
fYear
2003
fDate
4-6 Aug. 2003
Firstpage
1661
Abstract
Isometric tension and isotonic displacement generated by a solid polymer electrolyte membrane-gold (SPM-gold) was measured. SPM-gold was prepared by first immersing Nafion 117 to [Au(phen)Cl/sub 2/]+ solution and subsequently reducing gold particles on the surface of the membrane with Na/sub 2/SO/sub 3/. SPM-gold was cut in rectangular shape, and was set on an isometric and isotonic transducers (Nihon Kohden). Generated tension in isometric measurements and observed displacement in isotonic measurements showed linear relationship with applied voltage but a nonlinear behavior appeared beyond certain limits.
Keywords
biomedical materials; biomembranes; displacement measurement; gold; polymer electrolytes; prosthetics; solid electrolytes; gold particle; isometric displacement measurement; isometric tension; isometric transducers; isotonic displacement; isotonic tension measurement; isotonic transducers; solid polymer electrolyte membrane gold;
fLanguage
English
Publisher
ieee
Conference_Titel
SICE 2003 Annual Conference
Conference_Location
Fukui, Japan
Print_ISBN
0-7803-8352-4
Type
conf
Filename
1324223
Link To Document