• DocumentCode
    416980
  • Title

    Isotonic tension and isometric displacement measurement of a solid polymer electrolyte membrane-gold

  • Author

    Ihara, Tadashi ; Nakamura, Tatsuki ; Nakamura, Taro ; Ikada, Yoshito ; Asaka, Kinji ; Fujiwara, Naoko ; Oguro, Keisuke

  • Author_Institution
    Suzuka Univ. of Med. Sci., Japan
  • Volume
    2
  • fYear
    2003
  • fDate
    4-6 Aug. 2003
  • Firstpage
    1661
  • Abstract
    Isometric tension and isotonic displacement generated by a solid polymer electrolyte membrane-gold (SPM-gold) was measured. SPM-gold was prepared by first immersing Nafion 117 to [Au(phen)Cl/sub 2/]+ solution and subsequently reducing gold particles on the surface of the membrane with Na/sub 2/SO/sub 3/. SPM-gold was cut in rectangular shape, and was set on an isometric and isotonic transducers (Nihon Kohden). Generated tension in isometric measurements and observed displacement in isotonic measurements showed linear relationship with applied voltage but a nonlinear behavior appeared beyond certain limits.
  • Keywords
    biomedical materials; biomembranes; displacement measurement; gold; polymer electrolytes; prosthetics; solid electrolytes; gold particle; isometric displacement measurement; isometric tension; isometric transducers; isotonic displacement; isotonic tension measurement; isotonic transducers; solid polymer electrolyte membrane gold;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    SICE 2003 Annual Conference
  • Conference_Location
    Fukui, Japan
  • Print_ISBN
    0-7803-8352-4
  • Type

    conf

  • Filename
    1324223