• DocumentCode
    4240
  • Title

    A 3-D Self-Organized Leader Propagation Model and Its Engineering Approximation for Lightning Protection Analysis

  • Author

    Yazhong Xu ; Mingli Chen

  • Author_Institution
    Dept. of Building Services Eng., Hong Kong Polytech. Univ., Kowloon, China
  • Volume
    28
  • Issue
    4
  • fYear
    2013
  • fDate
    Oct. 2013
  • Firstpage
    2342
  • Lastpage
    2355
  • Abstract
    This paper presents a 3-D self-organized model of a downward stepped leader in negative cloud-to-ground lightning. In the model, the characteristic features of stepped leaders are generalized, so that parameters, such as the charge density along with the leader channel, leader corona sheath radius, leader step length, step time interval, and step advance speed, are calculated. Stepwise growth of the 3-D leader channel is developed stochastically. Parameters predicted by the model are qualitatively compatible with observation results, while the engineering approximation of the model for convenient lightning protection analysis is derived thereafter. The model is operated under various conditions at different leader initiation heights and electric potentials. Based on statistics of the simulation results, analytical relationships between the height and potential of leader initiation in the cloud and the charge distribution along the leader channel are approximated. Moreover, the lightning striking distance to flat ground is defined and calculated. Depending on the present model, the striking distance is found to be well associated with the charge density (or electrical potential) of the leader tip near to ground rather than the total charge in the leader channel. Based on appropriate physical understanding, the striking distance is connected to the return stroke peak current.
  • Keywords
    corona; lightning protection; 3D self-organized leader propagation model; charge density; charge distribution; downward stepped leader; electric potentials; engineering approximation; flat ground; leader channel; leader corona sheath radius; leader initiation heights; leader initiation potential; leader step length; lightning protection analysis; lightning striking distance; negative cloud-to-ground lightning; return stroke peak current; step advance speed; step time interval; Electric breakdown; Electric potential; Electrostatic processes; Lightning; Lightning protection; Propagation; Electrostatic processes; lightning protection; stepped leader modeling; striking distance;
  • fLanguage
    English
  • Journal_Title
    Power Delivery, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8977
  • Type

    jour

  • DOI
    10.1109/TPWRD.2013.2263846
  • Filename