DocumentCode
425635
Title
Energetically optimized control of an electric arc furnace
Author
Görtler, Gregor ; Jörgl, H. Peter
Author_Institution
Vienna Univ. of Technol., Austria
Volume
1
fYear
2004
fDate
2-4 Sept. 2004
Firstpage
137
Abstract
The control concept described here is based on an existing control system for three phase arc furnaces that uses the impedances of the three phases as control variables. It calculates the impedance set points in such a way that the electrical energy is optimally transferred into the scrap without damaging the furnace vessel. To keep the abrasion of the furnace vessel as small as possible the temperatures of the water cooled panels are measured. With a fuzzy algorithm the temperatures of each cooling panel and their time gradients are transformed into a so-called abrasion signal, which is the controlled variable of a superior control loop. The control concept was tested on a 50 t three-phase arc furnace. Exemplary results are presented.
Keywords
arc furnaces; electric variables control; fuzzy set theory; optimal control; power system control; temperature control; abrasion signal; electric arc furnace; electrical energy; furnace vessel; fuzzy algorithm; impedance set points; optimal control; three phase arc furnaces; three phase impedance; time gradients; water cooled panels; Control systems; Cooling; Costs; Electric resistance; Electric variables control; Electrodes; Furnaces; Impedance; Production; Steel;
fLanguage
English
Publisher
ieee
Conference_Titel
Control Applications, 2004. Proceedings of the 2004 IEEE International Conference on
Print_ISBN
0-7803-8633-7
Type
conf
DOI
10.1109/CCA.2004.1387200
Filename
1387200
Link To Document