• DocumentCode
    429044
  • Title

    Stationarity study of the myoelectrical signal recorded from small bowel

  • Author

    Garcia-Casado, J. ; Martinez-de-Juan, J.L. ; Meseguer, M. ; Ponce, J.L.

  • Author_Institution
    Univ. Politecnica de Valencia, Spain
  • Volume
    1
  • fYear
    2004
  • fDate
    1-5 Sept. 2004
  • Firstpage
    110
  • Lastpage
    113
  • Abstract
    Electroenterogram (EEnG) is the myoelectrical signal recorded from small intestine. Due to the relationship between mechanical activity and myoelectrical activity of the intestinal smooth muscle, EEnG could be a solution for quantifying intestinal motility. Motility indexes are traditionally calculated from 1-minute window analysis. However, no prior works have analyzed whether signal properties remain constant or not within this time interval. The aim of present paper is to study time evolution of changes in EEnG spectrum in order to determine if traditional analysis and window length is satisfactory from the signal dynamics point of view. Mechanical and electrical activities are recorded simultaneously in bowel rings (at duodenum, angle of Treitz and jejunum) of three Beagle dogs. Thirteen recording sessions were carried out. A stationary index (SI) based on statistical analysis of time evolution of spectral parameters is defined and calculated over EEnG recording sessions. Results show that myoelectrical signal from bowel muscle is stationary during quiescence periods and maximum contractions periods. However, during irregular contractile activity (i.e. transitions from no-activity to maximum activity, or in fed state) electroenterogram is a non-stationary signal if 1-minute length is chosen for its analysis. Therefore, traditional intestinal motility indexes must be redefined using non-stationary techniques.
  • Keywords
    biomechanics; electromyography; medical signal processing; spectral analysis; statistical analysis; 1 min; Beagle dogs; angle of Treitz; bowel muscle; duodenum; electroenterogram; intestinal motility; intestinal smooth muscle; jejunum; mechanical activity; myoelectrical signal; small bowel; small intestine; spectral parameters; stationarity study; statistical analysis; time evolution; Bioelectric phenomena; Calibration; Dogs; Intestines; Muscles; Pathology; Rhythm; Signal analysis; Statistical analysis; Surgery; Electroenterogram; Intestinal Motility; Small Bowel; Stationarity;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2004. IEMBS '04. 26th Annual International Conference of the IEEE
  • Conference_Location
    San Francisco, CA
  • Print_ISBN
    0-7803-8439-3
  • Type

    conf

  • DOI
    10.1109/IEMBS.2004.1403103
  • Filename