DocumentCode
432381
Title
Electrode area of breakdown depending on conditioning mechanism under non-uniform electric field in vacuum
Author
Okubo, Hisanori ; Miyazaki, Fumio ; Inagawa, Y. ; Kato, Kazuhiko ; Sakaki, Masayuki ; Ichikawa, H.
Author_Institution
Nagoya University, Nagoya, JAPAN
Volume
1
fYear
2004
fDate
Sept. 27 2004-Oct. 1 2004
Firstpage
76
Lastpage
79
Abstract
In this paper, we discussed the breakdown (BD) area of electrode on conditioning characteristics under non-uniform electric field in vacuum. Negative standard lightning impulse voltage was applied between rod and plane electrodes made of Cu-Cr and stainless steel for different tip radii and gap lengths. Experimental results revealed how the electrode area of BD and the BD field strength depend on the electric field distribution and the electrode materials in the conditioning process. As a result, we quantitatively clarified the relationship between electrode area of BD and conditioning mechanism under non-uniform electric field in vacuum.
Keywords
Breakdown voltage; Dielectrics and electrical insulation; Electrodes; History; Lightning; Nonuniform electric fields; Power systems; Steel; Vacuum breakdown; Vacuum systems;
fLanguage
English
Publisher
ieee
Conference_Titel
Discharges and Electrical Insulation in Vacuum, 2004. Proceedings. ISDEIV. XXIst International Symposium on
Conference_Location
Yalta, Crimea
ISSN
1093-2941
Print_ISBN
0-7803-8461-X
Type
conf
DOI
10.1109/DEIV.2004.1418605
Filename
1418605
Link To Document