Title :
Double bulk current injection: a new harness setup to correlate immunity test methods
Author :
Cuvelier, M. ; Rioult, J. ; Klingler, M. ; Ficheux, S.
Author_Institution :
INRETS, Villeneuve d´´Ascq
Abstract :
Double bulk current injection (DBCI) method has been proposed to reproduce the same current injection obtained in the case of an electromagnetic coupling with an incident plane wave. Good correlation can be obtained between this DBCI method and the stripline method, and also between DBCI and anechoic chamber methods. But there is no simultaneous correlation between these three methods because the stripline and the anechoic chamber methods are not based on the same coupling modes. This paper proposes a new harness setup conserving the standard harness length of 1 metre, in order to obtain a good correlation between all three test methods. The experimental validation given in this paper shows very encouraging results
Keywords :
anechoic chambers (electromagnetic); electromagnetic coupling; immunity testing; BCI; DBCI method; anechoic chamber; automotive equipment; double bulk current injection; electromagnetic coupling; harness setup; immunity test; incident plane wave; stripline method; Anechoic chambers; Automotive engineering; Conductors; Electromagnetic coupling; Electronic equipment; Electronic equipment testing; Frequency; Immunity testing; Qualifications; Stripline;
Conference_Titel :
Electromagnetic Compatibility, 2003. EMC '03. 2003 IEEE International Symposium on
Conference_Location :
Istanbul
Print_ISBN :
0-7803-7779-6
DOI :
10.1109/ICSMC2.2003.1428235