• DocumentCode
    434425
  • Title

    A factorial designed experiment for evaluation of mode-stirrers in reverberation chambers

  • Author

    Lundén, Olof ; Bäckström, Mats

  • Author_Institution
    FOI Swedish Defence Res. Agency, Linkoping
  • Volume
    1
  • fYear
    2003
  • fDate
    16-16 May 2003
  • Firstpage
    465
  • Abstract
    A factorial designed experiment at two levels was applied to investigate the performance of stirrers in reverberation chambers. The goal has been to quantify the sensitivity of the design parameters for the mode-stirrer. The focus has been to investigate single rotational stirrers. The experiment shows that the effect of changing the diameter of the stirrer is much greater than changing the height, and that the effect of changing the chamber volume is small
  • Keywords
    design of experiments; electromagnetic compatibility; electromagnetic devices; reverberation chambers; sensitivity; EMC; design of experiment; design parameters sensitivity; factorial designed experiment; mode-stirrers; reverberation chambers; single rotational stirrers; stirrer efficiency; Antenna measurements; Autocorrelation; Calibration; Electromagnetic compatibility; Frequency; Performance evaluation; Reverberation chamber; Testing; US Department of Energy; Uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2003. EMC '03. 2003 IEEE International Symposium on
  • Conference_Location
    Istanbul
  • Print_ISBN
    0-7803-7779-6
  • Type

    conf

  • DOI
    10.1109/ICSMC2.2003.1428292
  • Filename
    1428292