DocumentCode :
437992
Title :
A custom 96-channel VME TDC for the CDF detector for Tevatron collider run II
Author :
Moore, Ronald S.
Author_Institution :
Fermi Nat. Accel. Lab., USA
Volume :
3
fYear :
2004
fDate :
16-22 Oct. 2004
Firstpage :
1692
Abstract :
A 96-channel TDC (time to digital converter) VME board was designed for the CDF detector in Tevatron collider run II at Fermilab. The features include: a custom ASIC (application specific integrated circuit) component that provides time measurements of signals from the various detector elements; a DSP (digital signal processor) that formats the digitized data sent to the data acquisition system; a built-in diagnostic system; a VME interface to read out the data and control the board configuration. This TDC board implements the CDF data acquisition and trigger protocols. The TDCs were designed initially to achieve 300 Hz readout rate. More than 400 of these TDCs provide 1 ns resolution timing for signal pulses from wire chambers, scintillator panels, and calorimeter towers. In addition, custom daughter boards connected to the TDCs provide data to the level-1 trigger system. We describe the functionality of the TDC boards and performance during run II operation.
Keywords :
application specific integrated circuits; data acquisition; ionisation chambers; nuclear electronics; particle calorimetry; readout electronics; scintillation counters; signal processing; CDF data acquisition; CDF detector; Fermilab; Tevatron collider; VME interface; application specific integrated circuit; board configuration; built-in diagnostic system; calorimeter towers; custom ASIC component; custom daughter boards; digital signal processor; digitized data; level-1 trigger system; readout rate; scintillator panels; signal pulses; time-digital converter VME board; trigger protocols; wire chambers; Application specific integrated circuits; Control systems; Data acquisition; Detectors; Digital signal processing; Digital signal processors; Protocols; Signal processing; Signal resolution; Time measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2004 IEEE
Conference_Location :
Rome
ISSN :
1082-3654
Print_ISBN :
0-7803-8700-7
Electronic_ISBN :
1082-3654
Type :
conf
DOI :
10.1109/NSSMIC.2004.1462566
Filename :
1462566
Link To Document :
بازگشت