DocumentCode
438006
Title
Range measurements using visible scintillation light for proton therapy
Author
Hamada, M. ; Kodama, K. ; Tachibana, H. ; Nishio, T. ; Maruyama, K.
Author_Institution
Graduate Sch. of Med. Sci., Kitasato Univ., Sagamihara, Japan
Volume
3
fYear
2004
fDate
16-22 Oct. 2004
Firstpage
1776
Abstract
Proton beam therapy has certain advantages over that with the photon: a well-defined range, relatively little scattering, and high-energy deposition in the Bragg peak area. The depth dose distribution of proton beams shows a prominent Bragg peak at the end of the range, beyond which the dose rapidly falls to zero. Therefore, proton therapy makes possible to concentrate dose on tumor without increasing exposure on normal tissue. As a tool of daily treatment, an easy-to-use reliable range measurements method is required. We examined a method using visible scintillation light. We recorded visible scintillation light generated by proton irradiation on a block of plastic scintillator, and analyzed the length, shapes and brightness distribution to obtain the range, the magnitude of multiple Coulomb scattering and the depth dose distribution. The precision of the range measurement is 0.7 mm. The relation between proton range in plastic scintillator and that in water shows good linearity, because physical property of plastic scintillator and that of water have some similarity. Estimation of the depth dose distribution by measuring the brightness distribution was possible with a digital video camera. This measurement method is proved to be an easy-to-handle way as a tool for QA/QC of proton therapy. The depth dose measurements within this accuracy provide critical data for testing the treatment-planning program for proton therapy using the GEANT4 code.
Keywords
proton effects; radiation therapy; solid scintillation detectors; 0.7 mm; Bragg peak; GEANT4 code; brightness distribution; depth dose distribution; digital video camera; high-energy deposition; multiple Coulomb scattering; normal tissue; plastic scintillator; proton beam therapy; proton irradiation; range measurements; treatment-planning program testing; tumor; visible scintillation light; Brightness; Light scattering; Medical treatment; Neoplasms; Particle beams; Particle scattering; Plastics; Protons; Shape; Water;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2004 IEEE
Conference_Location
Rome
ISSN
1082-3654
Print_ISBN
0-7803-8700-7
Electronic_ISBN
1082-3654
Type
conf
DOI
10.1109/NSSMIC.2004.1462586
Filename
1462586
Link To Document