Title :
Combined clinical PET/CT and microPET small animal imaging
Author :
Yap, J.T. ; Hall, N.C. ; Townsend, D.W. ; Wall, J.S. ; Solomon, A. ; Kabalka, J.W. ; Kennel, S.J. ; Newport, D.F. ; Siegel, S.B. ; Bailey, D. ; Smith, A.M. ; Nutt, R.E.
Author_Institution :
Cancer Imaging & Tracer Dev. Program, Univ. of Tennessee Med. Center, Knoxville, TN
Volume :
5
fYear :
2004
fDate :
16-22 Oct. 2004
Firstpage :
2995
Lastpage :
2998
Abstract :
Recent advances in multi-detector CT design have enabled isotropic sub-millimeter spatial resolution. Although dedicated small animal CT scanners have been developed, the latest generation of high-performance clinical CT scanners may have sufficient spatial resolution for the purposes of small animal imaging. We have investigated the use of a clinical 16-slice PET/CT scanner in combination with the microPETreg scanner for rodent imaging. A method for co-registering PET/CT and microPET images was developed to improve the anatomical localization of PET uptake and perform attenuation and scatter correction. CT and PET visible fiducial markers containing a 68Ge point source are attached to a flat platform used in both the microPETreg and PET/CT imaging sessions to perform landmark based co-registration of the CT and microPETreg images. An automated registration method based on mutual information was also evaluated. The co-registered CT images were segmented into bone, soft tissue, and lungs and the respective attenuation coefficients at 511 keV were used to generate a transmission image for attenuation and scatter correction. Using this approach, high resolution co-registered CT and microPETreg images were obtained without the need for a dedicated small animal CT scanner or traditional PET transmission scanning. This improves the intreptation of microPET images and the correction for attenuation and scatter may be important when scanning larger species or multiple animals simultaneously
Keywords :
bone; image registration; image resolution; image scanners; lung; medical image processing; positron emission tomography; 68Ge point source; attenuation coefficients; bone; clinical PET/CT imaging; high resolution co-registered CT images; isotropic submillimeter spatial resolution; lungs; microPET small animal imaging; rodent imaging; scatter correction; small animal CT scanners; soft tissue; transmission image; Animals; Attenuation; Computed tomography; High-resolution imaging; Mutual information; Optical imaging; Positron emission tomography; Rodents; Scattering; Spatial resolution;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2004 IEEE
Conference_Location :
Rome
ISSN :
1082-3654
Print_ISBN :
0-7803-8700-7
Electronic_ISBN :
1082-3654
Type :
conf
DOI :
10.1109/NSSMIC.2004.1466314
Filename :
1466314
Link To Document :
بازگشت