DocumentCode :
438590
Title :
High resolution X-ray analysis of a proximal human femur with synchrotron radiation and an innovative linear detector
Author :
Bettuzzi, Matteo ; Brancaccio, Rosa ; Casali, Franco ; Cornacchia, Samantha ; Di Nicola, Emilia ; Lanconelli, Nico ; Mancini, Lucia ; Morigi, Maria Pia ; Pasini, Alessandro ; Romani, Davide ; Rossi, Alberto
Author_Institution :
Phys. Dept., Bologna Univ., Italy
Volume :
5
fYear :
2004
fDate :
16-22 Oct. 2004
Firstpage :
3312
Abstract :
Synchrotron based digital radiography and micro tomography devices are powerful, non-destructive, high-resolution research tools. In this study, we present a linear system capable of a nominal spatial resolution of 22.5 micrometers over a Field-Of-View (FOV) of 13 cm long and about 1 mm high. The system is composed of a linear converter GOS screen coupled to an intensified Electron-Bombarded CCD (EBCCD) camera, by means of a rectangular-to-linear fiber optic adapter. This optical guide is composed of seven bundles, each one transporting light in a coherent way to preserve spatial information. In this way, a high spatial resolution over an extended FOV is obtained The detector works as an X-ray scanner by means of a high-precision translation mechanical device. Here we present an investigation gained at ELETTRA synchrotron facility at Trieste (Italy). A monochromatic 34 keV has been used for imaging a human proximal femur, 9 cm in width, with our system. The excellent spatial resolution of the system allows the analysis of the trabecular structure of the bone over the entire FOV of about 10 cm.
Keywords :
CCD image sensors; X-ray analysis; bone; diagnostic radiography; image scanners; synchrotron radiation; ELETTRA synchrotron facility; Field-Of-View; Italy; Trieste; X-ray scanner; bone; digital radiography; high resolution X-ray analysis; high-precision translation mechanical device; innovative linear detector; intensified Electron-Bombarded CCD camera; linear converter GOS screen; linear system; microtomography devices; nominal spatial resolution; nondestructive research tools; optical guide; proximal human femur; rectangular-to-linear fiber optic adapter; synchrotron radiation; trabecular structure; Humans; Linear systems; Optical coupling; Radiation detectors; Radiography; Spatial resolution; Synchrotron radiation; Tomography; X-ray detection; X-ray detectors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2004 IEEE
ISSN :
1082-3654
Print_ISBN :
0-7803-8700-7
Electronic_ISBN :
1082-3654
Type :
conf
DOI :
10.1109/NSSMIC.2004.1466398
Filename :
1466398
Link To Document :
بازگشت