DocumentCode :
438618
Title :
Performance amelioration for small animal SPECT using optimized pinhole collimator and image correction technique
Author :
Song, Tae Yong ; Choi, Yong ; Chung, Yong Hyun ; Jung, Jin Ho ; Min, Byung Jun ; Hong, Key Jo ; Choe, Yearn Seong ; Lee, Kyung-Han ; Kim, Byung-Tae
Author_Institution :
Nucl. Medicine Dept., Sung Kyun Kwan Univ., Seoul, South Korea
Volume :
6
fYear :
2004
fDate :
16-22 Oct. 2004
Firstpage :
3458
Abstract :
The aim of this study was to improve the performance of pinhole single photon emission computed tomography (SPECT) fabricated with a position sensitive photomultiplier tube using optimized pinhole collimator and image correction technique. The center-of-rotation was aligned to prevent mechanical shift using a leveling-laser system. Based on the previous results of pinhole aperture simulation and optimization study, a pinhole collimator for the small animal SPECT was fabricated in the range of optimal pinhole diameter and channel height. Previously reported image correction technique of position mapping, energy calibration and flood correction procedures developed for array type scintillator was revised and applied to plate type crystal. Phantom and small animal studies were performed to investigate the system performance. Image correction technique, center-of-rotation alignment, and collimator optimization were necessary to obtain high resolution and high quality SPECT image. The SPECT system ameliorated by this study could be utilized in small animal and molecular imaging study required to provide high spatial resolution with moderate sensitivity.
Keywords :
collimators; gamma-ray detection; laser applications in medicine; photomultipliers; position sensitive particle detectors; single photon emission computed tomography; SPECT; amelioration; array type scintillator; center-of-rotation; energy calibration; flood correction procedure; image correction technique; leveling-laser system; mechanical shift; molecular imaging; pinhole aperture simulation; pinhole collimator; plate type crystal; position mapping; position sensitive photomultiplier tube; Animals; Apertures; Calibration; Computational modeling; Floods; Imaging phantoms; Optical collimators; Photomultipliers; Single photon emission computed tomography; Spatial resolution;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2004 IEEE
ISSN :
1082-3654
Print_ISBN :
0-7803-8700-7
Electronic_ISBN :
1082-3654
Type :
conf
DOI :
10.1109/NSSMIC.2004.1466631
Filename :
1466631
Link To Document :
بازگشت