Title :
Comparison of noise equivalent count rates and image noise
Author :
Dahlbom, Magnus ; Schiepers, Christiaan ; Czernin, Johannes
Author_Institution :
Dept. of Molecular & Med. Pharmacology, David Sch. of Medicine, Los Angeles, CA, USA
Abstract :
The aim of this study was to investigate the correlation between Noise Equivalent Count (NEC) Rates and the signal-to-noise ratio (S/N) in the reconstructed images. NEC rates were determined using uniform 20 cm and 60 cm tall, 20 cm diameter cylinders filled with 18F. The phantoms were scanned in both 2D and 3D mode. The reconstructed image noise, for each frame, was estimated using the bootstrap method. For each acquired frame, 250 sinogram replicates were generated (prompts and randoms, separately), which were reconstructed using FBP and OSEM (2i8s and 4i8s). The images were filtered to a final image resolution of 6 mm. From the reconstructed image sets, mean and standard deviation images were generated, from which the average image S/N (=mean/standard deviation) was calculated within a 5 cm central ROI. The effect of applying variance reduction processing on the random events, prior to subtraction from the prompt events, on the image noise was also investigated. The NEC was found to have a linear relationship to the square of the image S/N, where the only difference found was in the slope between different reconstruction methods, implying a difference in noise properties specific to the reconstruction algorithm. The linear relationship was also found in both 2D and 3D acquisition modes, as well as for the different activity distributions. The randoms processing showed an improvement in image S/N, consistent with a near noise-less estimate of the random rate. These results indicate that the NEC is not only a measure to compare the count rate performance of imaging systems, but this measure also translate into a measure for comparing image noise.
Keywords :
bootstrapping; fluorine; image reconstruction; image resolution; medical image processing; optimisation; phantoms; positron emission tomography; 20 cm; 2D acquisition mode; 3D acquisition mode; 60 cm; 18F; bootstrap method; filtered-back projection; image noise; image reconstruction; image resolution; noise equivalent count rate; ordered subset expectation maximization; phantoms; sinogram; Biomedical imaging; Delay estimation; Equations; Image reconstruction; National electric code; Noise measurement; Positron emission tomography; Reconstruction algorithms; Scattering; Signal to noise ratio;
Conference_Titel :
Nuclear Science Symposium Conference Record, 2004 IEEE
Print_ISBN :
0-7803-8700-7
Electronic_ISBN :
1082-3654
DOI :
10.1109/NSSMIC.2004.1466671