DocumentCode :
438648
Title :
Advanced hardware architecture for on-line data acquisition in clinical 3-D PET: smart DRAM PCI Card for 14 M event/sec histogramming across terabytes of DRAM
Author :
Jones, W.F. ; Running, M. ; Draughn, L. ; Reed, J.
Author_Institution :
CPS Innovations of Knoxville, TN, USA
Volume :
6
fYear :
2004
fDate :
16-22 Oct. 2004
Firstpage :
3663
Abstract :
Clinical PET places a demanding burden on the data acquisition architecture - especially when using larger, higher sensitivity detector arrays coupled with demands for high patient throughput. Pure list-mode data acquisition can have limited acceptance due to either too-slow event-packet collection speeds and/or too-slow post-acquisition processing. The typical resolution for this problem has been to perform both LOR-to-bin mapping (rebinning) and histogramming (±unity to memory) in an on-line manner - i.e. projection space "sinograms" are generated during the acquisition while the patient is still in the tomograph. This article describes a new design for very-high-speed online histogramming hardware - the Smart DRAM PCI card. This hardware is significant in the quest to address the needs of fast on-line histogramming into large DRAM arrays. This card has an integral dual-Fibre-Channel interface for receiving (and retransmitting) PET bin-address packets. Also, the card has onboard quad-interleaved ECC DDR SDRAM (4 DIMMs & up to 4 G bytes total per card) with a demonstrated capacity for sustained histogramming rates in excess of 14 M events/sec The retransmit-packets-on-Fibre-Channel feature supports a daisy chain of multiple such Smart DRAM cards. This means the architecture can easily make terabytes of memory available for on-line generation of projection data. Support is planned for time-of-flight and weighted histogramming as well as online gating.
Keywords :
DRAM chips; computer architecture; data acquisition; medical computing; optical computing; peripheral interfaces; positron emission tomography; programming; LOR-to-bin mapping; PET bin-address packet; clinical 3-D PET; detector arrays; integral dual-Fibre-Channel interface; list-mode data acquisition; on-line data acquisition; online histogramming hardware architecture; projection space sinograms; rebinning; smart DRAM PCI card; DRAM chips; Data acquisition; Detectors; Hardware; Positron emission tomography; Random access memory; Sensor arrays; Technological innovation; Telephony; Throughput;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2004 IEEE
ISSN :
1082-3654
Print_ISBN :
0-7803-8700-7
Electronic_ISBN :
1082-3654
Type :
conf
DOI :
10.1109/NSSMIC.2004.1466676
Filename :
1466676
Link To Document :
بازگشت