• DocumentCode
    438705
  • Title

    Application of ordered-subsets expectation-maximization (OSEM) algorithm to cone-beam SPECT for accelerated 3D reconstruction

  • Author

    Krol, Andrzej ; Feiglin, David H. ; Lee, Wei ; Kunniyur, Vikram R. ; Salgado, Roberto B. ; Coman, Ioana L. ; Lipson, Edward D. ; Karczewski, Deborah A. ; Thomas, F. Deaver

  • Author_Institution
    Dept. of Radiol., State Univ. of New York, Syracuse, NY, USA
  • Volume
    6
  • fYear
    2004
  • fDate
    16-22 Oct. 2004
  • Firstpage
    3971
  • Abstract
    We investigated the performance of an ordered-subsets expectation-maximization (OSEM) algorithm for accelerated reconstruction in cone-beam SPECT. SPECT scans were performed using a Defrise phantom filled with 0.9μCi/ml of Tc-99m and a dual-head gamma camera equipped with one cone-beam (CBC, f=70 cm) and one parallel-beam collimator (PBC). Images were reconstructed using a fully-3D approach with resolution and attenuation modeling and an ordered-subsets version of a maximum-likelihood expectation-maximization algorithm (MLEM). Three grouping patterns of subsets were applied: consecutive, orthogonal, and uniform. In contrast to PBC SPECT, we observe that, in CBC SPECT, the reconstruction grouping pattern of the subsets is very important for the image quality obtained. Only when the projection data grouped into a subset were selected as uniformly as possible from all the acquired views, were the image quality and the noise in the images very close to results obtained using MLEM. However, we note that, for both CBC and PBC SPECT, the loglikelihood for a given iteration is practically the same for different grouping patterns of subsets.
  • Keywords
    collimators; image reconstruction; maximum likelihood estimation; medical image processing; phantoms; set theory; single photon emission computed tomography; technetium; Defrise phantom; OSEM; accelerated 3D image reconstruction; attenuation modeling; cone-beam SPECT; consecutive subset; dual-head gamma camera; image noise; image quality; ordered-subsets expectation-maximization algorithm; orthogonal subset; parallel-beam collimator; projection data; resolution modelling; uniform subset; Acceleration; Attenuation; Biomedical imaging; Cameras; Collimators; Image quality; Image reconstruction; Imaging phantoms; Radiology; Telephony;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2004 IEEE
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-8700-7
  • Electronic_ISBN
    1082-3654
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2004.1466747
  • Filename
    1466747