DocumentCode
448541
Title
Effects of slot combination and skewed slot on the electromagnetic vibration of a 4-pole capacitor motor under load condition
Author
Hirotsuka, Isao ; Tsubouchi, Yutaro ; Tsuboi, Kazuo
Author_Institution
Chubu Univ., Aichi, Japan
Volume
1
fYear
2005
fDate
27-29 Sept. 2005
Firstpage
138
Abstract
Recently, the reduction of electromagnetic vibration and noise of a capacitor motor (CRM) has become a very important subject from the standpoint of environmental improvement. Therefore, the authors have studied the characteristics of the dominant electromagnetic vibration of the CRM under load condition. In this paper, the effects of slot combination and skewed slot on the dominant electromagnetic vibration of a CRM under load condition are discussed both theoretically and experimentally. As a result, the characteristics of the dominant electromagnetic vibration for the slot combination and the reduction effect of the skewed slot on the electromagnetic vibration are clarified for a 4-pole CRM.
Keywords
acoustic noise; capacitor motors; electromagnetic forces; vibrations; 4-pole capacitor motor; electromagnetic vibration reduction; noise reduction; skewed slot; slot combination; standard block; Capacitors; Electromagnetic fields; Electromagnetic forces; Electromagnetic interference; Electronic mail; Frequency; Noise reduction; Rotors; Stators; Working environment noise; backward magnetic field; capacitor motor; electromagnetic force wave; electromagnetic vibration; skewed slot; slot combination;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines and Systems, 2005. ICEMS 2005. Proceedings of the Eighth International Conference on
Print_ISBN
7-5062-7407-8
Type
conf
DOI
10.1109/ICEMS.2005.202501
Filename
1574734