Title :
Response of a SOI microdosimeter to a /sup 238/PuBe neutron source
Author :
Reinhard, M.I. ; Cornelius, I. ; Prokopovich, D.A. ; Wroe, A. ; Rosenfeld, A.B. ; Pisacane, V. ; Ziegler, J.F. ; Nelson, M.E. ; Cucinotta, F. ; Zaider, M. ; Dicello, J.F.
Abstract :
The response of a solid state microdosimeter based on semiconductor on insulator (SOI) technology to a 238PuBe neutron source was investigated. Simulations of the device response using the GEANT4 Monte Carlo toolkit are also presented. The microdosimetric spectra was measured for lineal energies above 1 keV/mum. The possible application of the SOI microdosimeter for radiation protection applications in the form of a personnel microdosimeter is suggested
Keywords :
Monte Carlo methods; dosimeters; radiation protection; semiconductor-insulator boundaries; 238PuBe neutron source; GEANT4 Monte Carlo toolkit; SOI microdosimeter; personnel microdosimeter; radiation protection; semiconductor on insulator technology; solid state microdosimeter; Australia; Current measurement; Detectors; NASA; Neutrons; Nuclear and plasma sciences; P-n junctions; Silicon on insulator technology; Space technology; Topology;
Conference_Titel :
Nuclear Science Symposium Conference Record, 2005 IEEE
Conference_Location :
Fajardo
Print_ISBN :
0-7803-9221-3