DocumentCode :
451565
Title :
VAS/spl I.bar/UM/TAT4 ASIC readout systems for 3D CdZnTe/HgI/sub 2/ detector arrays
Author :
Zhang, Feng ; He, Zhong
Author_Institution :
Dept. of Nucl. Eng. & Radiol. Sci., Michigan Univ., Ann Arbor, MI
Volume :
2
fYear :
2005
fDate :
23-29 Oct. 2005
Firstpage :
950
Lastpage :
954
Abstract :
The 4th-generation readout systems based on VAS_UM/TAT4 ASICs for 3-D position sensitive CdZnTe/HgI2 detector arrays have been developed and tested. Each VAS_UM/TAT4 chip is a 129-channel self-triggered monolithic application specific integrated circuitry (ASIC). One 3-D position-sensitive detector module consists of one CdZnTe or HgI2 gamma-ray spectrometer, and one VAS_UM/TAT4 ASIC mounted on a 2.2 times 2.2 cm2 front-end board. Each detector has an array of 11 by 11 pixel anodes fabricated on the anode surface with an area up to 2 by 2 cm2. The detector and the front-end board are connected by three pairs of 42-pin connectors for easy assemble and component replacement. Up to nine detector modules can be plugged in to a single motherboard to form a 3 by 3 detector array. The VAS_UM/TAT4 chip can read out both the amplitude of induced charge on each electrode and the electron drift time needed for reconstructing energy deposition and three-dimensional coordinates of each radiation interaction. Three different sets of VAS_UM/TAT4 chips were fabricated - the first set is for intermediate energy gamma-ray spectroscopy on CdZnTe with a dynamic range up to 1 MeV per channel. The second set is for higher-energy gamma-ray detection in CdZnTe for energy deposition of up to 3 MeV per channel, and the third set is for HgI2 gamma-ray spectrometers (up to 1 MeV per channel). These are the first ASIC readout systems that allow multiple 3-D position sensitive CdZnTe/HgI2 detector modules to be tiled together, to achieve detection volume greater than 50 cm3 on a single detector plane. Multiple planes of detector arrays can be operated together to achieve more than 100 cm3 detection volume and beyond on a single system. In this paper, VAS_UM/TAT4 ASIC systems are described and their test results will be reported
Keywords :
application specific integrated circuits; gamma-ray detection; gamma-ray spectrometers; nuclear electronics; position sensitive particle detectors; readout electronics; semiconductor counters; 11 pixel; 2.2 cm; 3-D position sensitive CdZnTe/HgI2 detector arrays; 3-D position-sensitive detector module; ASIC; CdZnTe gamma-ray spectrometer; HgI2 gamma-ray spectrometer; VAS_UM/TAT4 ASIC readout systems; VAS_UM/TAT4 chip; electrode; electron drift time; energy deposition; front-end board; higher-energy gamma-ray detection; induced charge amplitude; intermediate energy gamma-ray spectroscopy; self-triggered monolithic application specific integrated circuitry; three-dimensional radiation interaction; Anodes; Application specific integrated circuits; Circuit testing; Connectors; Gamma ray detection; Gamma ray detectors; Position sensitive particle detectors; Sensor arrays; Spectroscopy; System testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2005 IEEE
Conference_Location :
Fajardo
ISSN :
1095-7863
Print_ISBN :
0-7803-9221-3
Type :
conf
DOI :
10.1109/NSSMIC.2005.1596411
Filename :
1596411
Link To Document :
بازگشت