ATLAS US muon endcap MDT chamber performance in pre-commissioning
Author :
Ferretti, Claudio
Author_Institution :
Michigan Univ., MI, USA
Volume :
3
fYear :
2005
fDate :
23-29 Oct. 2005
Firstpage :
1447
Lastpage :
1451
Abstract :
The single chamber tests of the 240 monitored drift tube (MDT) chambers for almost 90,000 channels, built in the U.S. for the endcap sector of the ATLAS muon spectrometer have been completed. For the first time the results are being presented and show the perfect compliance with ATLAS specifications and a high level of uniformity.
Keywords :
drift chambers; muon detection; particle spectrometers; ATLAS US muon endcap monitored drift tube chamber; ATLAS muon spectrometer; CERN; detector control system; local monitor board; Argon; Control systems; Dark current; Detectors; Electronic equipment testing; Monitoring; Optical sensors; Performance evaluation; Temperature sensors; Voltage;