    Investigating pinhole SPECT for wrist imaging

  • Author

    Sabondjian, Eric ; Wells, R. Glenn

  • Author_Institution
    The Lawson Health Res. Inst., London, Ont., Canada
  • Volume
    4
  • fYear
    2005
  • fDate
    23-29 Oct. 2005
  • Firstpage
    2218
  • Lastpage
    2222
  • Abstract
    The wrist consists of eight small carpal bones, which may be as small as 1 cm3. This makes the wrist one of the most complex joints to image. Initial X-rays miss 35% of fractures. Planar nuclear medicine scans are available and add functional information over the anatomical X-ray image, but they lack in specificity. SPECT may increase specificity, but is limited by poor resolution. We hypothesize that by using pinhole collimators we can improve resolution, while maintaining sensitivity in the desired field of view (FOV). To measure sensitivity the counts obtained for each collimator were recorded. A 5 cm radius sphere was used as a volume of interest (VOI) for comparing the sensitivities between collimators. The Micro Deluxe phantom and a wrist phantom developed on site were used to measure and compare the resolution of a fanbeam collimator with a 3, 4, and 6 mm pinhole collimator at 6.5 and 7.5 cm radii of rotations. The same two phantoms were used to measure the resolution at different count levels to determine the relationship between resolution and sensitivity of the pinhole collimators. The sensitivity measured in the wrist VOI was shown to be slightly (30%) higher in the fanbeam collimator compared to the 3 mm pinhole. However, the 4 mm and 6 mm pinholes had an increase of 20% and 140% respectfully over the fanbeam collimator. We observed that increasing the sensitivity with a larger pinhole size does not improve resolution significantly. The best images were obtained using the smallest pinhole size (3 mm). With the 3 mm pinhole collimator at clinical count levels an average resolution of 4 mm was measured at by taking the FWHM of the derivative on the cube edge. Images of the Micro Deluxe Phantom at similar count levels confirmed this measurement.
  • Keywords
    bone; image resolution; medical image processing; phantoms; single photon emission computed tomography; Micro Deluxe Phantom; anatomical X-ray image; carpal bones; fanbeam collimator; pinhole SPECT; pinhole collimator resolution; pinhole collimator sensitivity; planar nuclear medicine scans; wrist imaging; Bones; Collimators; Computed tomography; Hospitals; Imaging phantoms; Injuries; Magnetic resonance imaging; Optical imaging; Wrist; X-rays;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2005 IEEE
  • ISSN
    1095-7863
  • Print_ISBN
    0-7803-9221-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2005.1596775
  • Filename
    1596775