DocumentCode
452851
Title
Different Results of Radiated Emissions in Fully and Semi-Anechoic Chamber due to Influence of EUT í s Vertical Cables Termination
Author
Kova, G. ; Lapuh, R.
Author_Institution
Slovenian Inst. of Quality & Metrol., Ljubljana
Volume
1
fYear
2005
fDate
16-19 May 2005
Firstpage
704
Lastpage
707
Abstract
Influence of EUT´s vertical cables termination in fully and semi-anechoic chamber has been investigated. Numerical calculation and experimental results are presented for end-driven wire model (EDW) of equipment under test (EUT) with one cable. The investigation shows comparable results in different type of chambers for EUTs with cables terminated with absorbing clamp
Keywords
anechoic chambers (electromagnetic); electromagnetic interference; electronic equipment testing; emission; power cables; EMC; absorbing clamp; anechoic chamber has; end-driven wire model; equipment under test; radiated emissions; vertical cables termination; Cable shielding; Current measurement; Electric variables measurement; Frequency measurement; Impedance measurement; Performance evaluation; Receiving antennas; Resonance; Resonant frequency; Transmitting antennas; EMC; absorbing clamps; radiated emission; termination;