DocumentCode :
454051
Title :
Research on isolated diesel-wind power system equipped with doubly fed induction generator
Author :
Qiao Jiageng ; Zongxiang, Lu ; Yong, Min
Author_Institution :
Dept. of Electr. Eng., Tsinghua Univ., Beijing, China
fYear :
2006
fDate :
28-31 March 2006
Firstpage :
246
Lastpage :
250
Abstract :
In this paper, we focus on a MW level diesel-wind power system consisting of a wind generator equipped with doubly fed induction generator (DFIG) and a diesel generator. Compared with the conventional diesel-wind system, the response of the system equipped with DFIG during wind fluctuation and load changes is more stable, and the ability for reactive power output of DFIG can improve the reactive power control in system operation observably. The performance of isolated diesel-wind power systems can be improved effectively by enhancing the wind generators. Analysis also shows that in this kind of system, the diesel generator terminal voltage and the upper limits for reactive power output of DFIG are important operative parameters affecting the operation performance.
Keywords :
asynchronous generators; diesel-electric generators; diesel-electric power stations; hybrid power systems; reactive power; wind power plants; wind turbines; diesel generator; diesel-wind power system; doubly fed induction generator; hybrid power system; power system operation; reactive power control; wind fluctuation; wind generator; wind turbine;
fLanguage :
English
Publisher :
iet
Conference_Titel :
AC and DC Power Transmission, 2006. ACDC 2006. The 8th IEE International Conference on
Conference_Location :
IET
ISSN :
0537-9989
Print_ISBN :
0-86341-613-6
Type :
conf
Filename :
1633651
Link To Document :
بازگشت