DocumentCode
460338
Title
Stress and Displacement in Cantilever-Based Transducers for Biosensing Application
Author
Bineva, I. ; Voicu, R. ; Esinenco, D. ; Dinescu, A. ; Muller, R. ; Bucur, B. ; Diaconu, M. ; Radu, L.G.
Author_Institution
INCD for Microtechnol., Bucharest
Volume
1
fYear
2006
fDate
27-29 Sept. 2006
Firstpage
223
Lastpage
226
Abstract
A cantilever array with dimensions of the beams 150times80times1.2 mum has been fabricated. Three different biochemical compounds were deposited and the cantilever was investigated using scanning electron microscopy (SEM). Simulations using CoventorWare have been made and stresses have been calculated between 12 and 60.4 MPa
Keywords
biomedical transducers; biosensors; cantilevers; scanning electron microscopy; 1.2 micron; 150 micron; 80 micron; CoventorWare simulation; SEM; biochemical compounds; biosensing application; cantilever array; cantilever-based transducers; scanning electron microscopy; Atomic force microscopy; Biosensors; Etching; Fabrication; Gold; Micromechanical devices; Scanning electron microscopy; Stress; Structural beams; Transducers; MEMS; biosensing; cantilever; simulations; stress; transducers;
fLanguage
English
Publisher
ieee
Conference_Titel
International Semiconductor Conference, 2006
Conference_Location
Sinaia
Print_ISBN
1-4244-0109-7
Type
conf
DOI
10.1109/SMICND.2006.283973