• DocumentCode
    462381
  • Title

    Fissile Mass Flow Monitor Source-Strength Calibration Using the ORNL Neutron Detector System

  • Author

    Uckan, Taner ; March-Leuba, Jose ; Powell, Danny

  • Author_Institution
    Oak Ridge Nat. Lab., TN
  • Volume
    1
  • fYear
    2006
  • fDate
    Oct. 29 2006-Nov. 1 2006
  • Firstpage
    540
  • Lastpage
    543
  • Abstract
    This paper describes the neutron detector system (NDS) developed to measure the neutron source strength of the 252Cf neutron sources used in the fissile mass flow monitor (FMFM). The FMFM measures the 235U fissile mass flow in the UF6 gas streams and uses 252Cf neutron sources for the fission activation of the UF6 gas. Four FMFMs are operational in three Russian facilities for the U.S. Department of Energy´s Highly Enriched Uranium Transparency Program. The 252Cf sources are replaced about every 2 years due to their short half-life (~2.65 years). During FMFM source replacement, the new 252Cf sources are calibrated and verified with the previously installed sources (i.e., a relative source mass check) to ensure proper and seamless FMFM performance. The NDS consists of a neutron detector (a commercially available high-efficiency 3He proportional counter) and the electronics, which are commercial nuclear instrument modules. A measurement time of 10 s is sufficient to take the data; the NDS yields about les 0.5% error from the average count taken up to 100 s. Measurement repeatability is good (< 1%), and it is not sensitive (< 0.5%) to the orientation of the source plug inside the NDS polyethylene source plug holder. The NDS is then calibrated for the measured source mass strength, and it is established that the sources can be measured with an overall uncertainty of 1.4% for a typical FMFM source mass of 3 mug. A detailed description of the NDS, its performance characteristics, and results of measurements performed on the latest FMFM sources are presented.
  • Keywords
    neutron detection; neutron sources; nuclear electronics; proportional counters; radiation monitoring; 235U fissile mass flow; 252Cf neutron sources; 3He proportional counter; FMFM source replacement; Highly Enriched Uranium Transparency Program; NDS; ORNL neutron detector system; fissile mass flow monitor; fission activation; neutron source strength measurement; nuclear instrument modules; relative source mass check; source strength calibration; uranium hexafluoride gas streams; Calibration; Counting circuits; Detectors; Fluid flow measurement; Helium; Monitoring; Neutrons; Nuclear electronics; Plugs; Time measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2006. IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1095-7863
  • Print_ISBN
    1-4244-0560-2
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2006.356215
  • Filename
    4179054