    Compensation for Patient and Detector Scatter and Crosstalk Contamination in 111In SPECT Using Fast Monte Carlo-based Iterative Reconstruction

  • Author

    Ouyang, Jinsong ; Fakhri, Georges El ; Zimmerman, Robert E. ; Moore, Stephen C.

  • Author_Institution
    Brigham & Women´´s Hosp., Boston, MA
  • Volume
    5
  • fYear
    2006
  • fDate
    Oct. 29 2006-Nov. 1 2006
  • Firstpage
    2851
  • Lastpage
    2853
  • Abstract
    We have developed a fast Monte Carlo (MC)-based joint ordered-subset expectation maximization (JOSEM) iterative reconstruction algorithm, MC-JOSEM. A phantom was scanned with CT and SPECT to compare quantitative imaging performance of MC-JOSEM with that of a triple-energy-window method (TEW) in which estimated scatter was also included additively within JOSEM, TEW-JOSEM. We acquired very-high-count projections of three 5.5-cc spheres of 111In taped in different locations in a water-filled torso/spine/lung phantom; 14 scans were then obtained with 111In only in the background for generating synthetic images of spheres in background. MC scatter estimates, which were used by MC-JOSEM, were computed once after 5 iterations (60 projections, 10 subsets) of TEW-JOSEM. Images after 36 iterations of both TEW-JOSEM and MC-JOSEM were obtained and counts were measured within volumes-of-interest centered on the spheres in all sphere+background and background-only image sets. The bias ranged from 7.7% to 14.1% for TEW-JOSEM, and from 8.9% to 11.3% for MC-JOSEM, while the precision was significantly better for MC-JOSEM (5.4% to 11.2%) than for TEW-JOSEM (9.2% to 17.9%). MC-JOSEM is a promising approach for quantitative SPECT.
  • Keywords
    Monte Carlo methods; bone; image reconstruction; iterative methods; lung; medical image processing; single photon emission computed tomography; 111In SPECT; Monte Carlo method; crosstalk contamination; detector scatter; iterative reconstruction; joint ordered-subset expectation maximization; lung phantom; patient scatter; single photon emission computed tomography; spine phantom; triple-energy-window method; water-filled torso phantom; Computed tomography; Contamination; Crosstalk; Detectors; Image reconstruction; Imaging phantoms; Monte Carlo methods; Reconstruction algorithms; Scattering; Torso;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2006. IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1095-7863
  • Print_ISBN
    1-4244-0560-2
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2006.356471
  • Filename
    4179628