Title :
Testing Needs for ITER ECH Transmission Line Components
Author :
Olstad, R.A. ; Doane, J.L. ; Callis, R.W.
Author_Institution :
Gen. Atomics, San Diego
Abstract :
The performance requirement of 1 (possibly 2) MW cw at 170 GHz for ITER electron cyclotron heating and current drive transmission line components is much more demanding than the 1 MW 10 s performance, generally at 110 GHz, that has been demonstrated on present devices. The high ITER heat loads will require enhanced cooling and, for some components, new or modified designs. Before component designs are finalized, testing at ITER conditions is strongly advisable.
Keywords :
fusion reactors; plasma radiofrequency heating; testing; waveguides; ITER ECH transmission line component; current drive transmission line component; electron cyclotron heating; frequency 110 GHz; frequency 170 GHz; power 1 MW; Cooling; Gyrotrons; Heating; Mirrors; Optical waveguides; Power transmission lines; Prototypes; Testing; Transmission lines; Waveguide components;
Conference_Titel :
Infrared Millimeter Waves and 14th International Conference on Teraherz Electronics, 2006. IRMMW-THz 2006. Joint 31st International Conference on
Conference_Location :
Shanghai
Print_ISBN :
1-4244-0400-2
Electronic_ISBN :
1-4244-0400-2
DOI :
10.1109/ICIMW.2006.368257