Title :
Analysis of the Experimental Results for Dry Band Arcing Deterioration of ADSS Fiber-Optic Cables in High Electric Field
Author :
Shikoski, J.D. ; Karady, G.G.
Author_Institution :
State Univ. Tetovo, Ohrid
Abstract :
In many instances, the ADSS cables are installed on the high voltage line. Because of the lack of the space, the distance between the line and the ADSS cable depends on the voltage. The cable is surrounded by a wire structure, which equalizes the distribution of the mechanical load. In a polluted environment, dry band arcing occurs, when fog or dew occasionally wets the cable. This also causes cable deterioration[l-4][7]. The conditions in the field were modeled in a HV laboratory at Arizona State University. The laboratory tests replicated the dry band arcing caused cable deterioration. In this paper the analysis of the experimental results are presented.
Keywords :
arcs (electric); electric fields; optical cables; ADSS fiber-optic cables; Arizona State University; HV laboratory; all dielectric self-supporting; cable deterioration; dry band arcing deterioration; high electric field; high voltage line; mechanical load distribution; wire structure; Arc discharges; Assembly; Communication cables; Conducting materials; Mechanical cables; Optical fiber cables; Optical fibers; Poles and towers; Power transmission lines; Voltage; dry band arcing; fiber-optic; partial discharge;
Conference_Titel :
Power Engineering Society General Meeting, 2007. IEEE
Conference_Location :
Tampa, FL
Print_ISBN :
1-4244-1296-X
Electronic_ISBN :
1932-5517
DOI :
10.1109/PES.2007.385525