DocumentCode :
468479
Title :
Thermal analysis on the stator of turbo-generators with hollow sub-conductor blockage
Author :
Lihui, Wang ; Junqing, Li ; Xiaorong, Zhang
Author_Institution :
North China Electr. Power Univ., Baoding
fYear :
2007
fDate :
8-11 Oct. 2007
Firstpage :
1080
Lastpage :
1083
Abstract :
In order to obtaining the necessary temperature reference values of a real time fault diagnosis simulate and study the temperature rise along the stator winding bar with hollow sub-conductor blockage to be essential in the fault diagnosis of large turbo-generators. This paper describes the stator 3D temperature field of the water cooling winding bar fault in three positions of turbo-generators. The thermal network method was used to model the stator 3D temperature field of generator. The result showed a severe temperature rise could be lead to in fault position around when the partial hollow cooling conductors was obstruction in the stator bars. The authors conclude the proposed model and calculation method is correct.
Keywords :
fault diagnosis; stators; thermal analysis; turbogenerators; hollow cooling conductor; real time fault diagnosis; stator winding bar; subconductor blockage; thermal analysis; turbo-generator; Bars; Condition monitoring; Conductors; Cooling; Copper; Fault diagnosis; Iron; Stator windings; Teeth; Temperature control;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Systems, 2007. ICEMS. International Conference on
Conference_Location :
Seoul
Print_ISBN :
978-89-86510-07-2
Electronic_ISBN :
978-89-86510-07-2
Type :
conf
Filename :
4411970
Link To Document :
بازگشت