• DocumentCode
    468650
  • Title

    Safe operating area of high power three-level neutral point clamped voltage source inverters equipped with IGCTs

  • Author

    Yuan, Liqiang ; Zhao, Zhengming ; He, Fanbo ; Eltawil, Mohd

  • Author_Institution
    Tsinghua Univ., Tsinghua
  • fYear
    2007
  • fDate
    8-11 Oct. 2007
  • Firstpage
    64
  • Lastpage
    68
  • Abstract
    To design and analyze the behavior of high power inverter, the definition and application of the inverter´s own safe operating area (SOA) are presented in this paper. The relation between the switch devices behaviors and the other components of the inverter is playing a key role in the description of the novel SOA. Based on the proposed idea, the optimization of a real 1.25 MW/3.3 kV inverter equipped with IGCTs is presented and analyzed. The corresponding experimental results are shown.
  • Keywords
    invertors; switches; IGCT; high power inverter; high power three level neutral point clamped voltage source inverters; safe operating area; switch devices behaviors; Circuits; Induction motors; Power harmonic filters; Power system simulation; Pulse width modulation inverters; Semiconductor optical amplifiers; Switches; Topology; Variable speed drives; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines and Systems, 2007. ICEMS. International Conference on
  • Conference_Location
    Seoul
  • Print_ISBN
    978-89-86510-07-2
  • Electronic_ISBN
    978-89-86510-07-2
  • Type

    conf

  • Filename