DocumentCode :
468698
Title :
Unbalanced magnetic pull induced by drive current in PM-BLDC motor operation
Author :
Bi, Chao ; Aung, Nay Lin Htun ; Phyu, Hla Nu ; Jiang, Quan ; Lin, Song
Author_Institution :
Data Storage Inst., Singapore
fYear :
2007
fDate :
8-11 Oct. 2007
Firstpage :
780
Lastpage :
785
Abstract :
In the applications of high performance permanent-magnetic brushless DC (PM-BLDC) motor, the effects of unbalanced-magnetic-pull (UMP) is very concerned. Besides the intrinsic and extrinsic reasons, the motor drive current may also be an UMP source if the armature winding design is not reasonable. This paper presents an analytic model for analyzing the UMP induced by electromagnetic (EM) structure and drive current of the PM-BLDC motor, and the model can simplify effectively the analysis procedure. The analysis shows that, the UMP induced by the drive current can be avoided by using the reasonable winding structure, magnetic pole-pairs and stator slot number. For verifying the effectiveness of the analytic method proposed, several PM-BLDC motors are analyzed with the numerical method to confirm the effectiveness of the UMP model presented.
Keywords :
brushless DC motors; permanent magnet motors; stators; PM-BLDC motor operation; armature winding design; electromagnetic structure; high performance permanent-magnetic brushless DC motor; magnetic pole-pairs; motor drive current; stator slot number; unbalanced magnetic pull; winding structure; Brushless DC motors; Brushless motors; DC motors; Electromagnetic analysis; Electromagnetic modeling; Magnetic analysis; Permanent magnet motors; Rotors; Stator cores; Stator windings;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Systems, 2007. ICEMS. International Conference on
Conference_Location :
Seoul
Print_ISBN :
978-89-86510-07-2
Electronic_ISBN :
978-89-86510-07-2
Type :
conf
Filename :
4412189
Link To Document :