PSPMT/APD hybrid DOI detectors for the PET component of a dedicated breast PET/CT system — A feasibility study
Author :
Chaudhari, Abhijit J. ; Yang, Yongfeng ; Farrell, Richard ; Dokhale, Purushottam A. ; Shah, Kanai S. ; Cherry, Simon R. ; Badawi, Ramsey D.
Author_Institution :
Univ. of California, Davis
Volume :
4
fYear :
2007
fDate :
Oct. 26 2007-Nov. 3 2007
Firstpage :
2851
Lastpage :
2858
Abstract :
We explore two depth of interaction (DOI) capable detectors with a high effective packing fraction to be used for the PET portion of a next generation cylindrical pendant breast PET/CT scanner. The proposed dual-readout detectors consist of an unpolished (14 times 14) array of (1.5 times 1.5 times 20) mm3 LSO crystals coupled to a position sensitive-PMT (PSPMT) at the back end for position sensing and either (A) a (2times2) matrix of avalanche photodiodes (APDs) or (B) a single large APD at the front end for measuring DOI. Increased effective packing fraction is achieved by choosing the APDs such that the total front surface contact area of the APD matrix or the single large APD approximately matches both the contact area of the crystal array and the active area of the PSPMT. This results in reduced dead space between adjacent detectors when placed in a cylindrical scanner geometry. We propose to recover DOI for the crystals that are partially occluded due to the inactive area of the APD by using the optical crosstalk from neighboring crystals. We conducted preliminary studies utilizing five prototype modules: two of which used a (9 times 9) array of (1.5 times 1.5 times 20) mm3 LSO crystals, and three that used a (14 times 14) LSO array of (1.5 times 1.5 times 30) mm3 crystals. The readout was performed either by a (8 times 8) mm2, (14 times 14) mm2 or a (28 times 28) mm2 position sensitive-APD (PSAPD) at the front end and a PSPMT at the rear end. At room temperature, the average energy and DOI resolutions degraded only by < 2% and < 0.3 mm respectively for edge crystals compared to the center crystals for all PSAPDs. The energy resolution and the DOI resolution for the detector design with readout (A) was estimated to be 14.2% and 3.97 mm, and that for the design with readout (B) was estimated at 14.7% and 4.1 mm. After cooling to 10degC, the performance of the second design was close to tha- t of the first design. We conclude that a dedicated cylindrical breast PET/CT scanner could be operated with either of the proposed DOI detector schemes, thus improving packing fraction, and hence, sensitivity and NEC. The two designs have different advantages and drawbacks: the first design performs well at room temperature, however, the readout is complex, while the second design has a simpler readout scheme but requires a cooling system for it to achieve optimal performance.
Keywords :
avalanche photodiodes; biomedical equipment; computerised tomography; mammography; position sensitive particle detectors; positron emission tomography; solid scintillation detectors; DOI resolution; LSO crystal array; PSPMT-APD hybrid DOI detectors; avalanche photodiodes; breast PET-CT system; cooling system; depth of interaction detectors; dual-readout detectors; effective packing fraction; energy resolution; optical crosstalk; position sensitive-PMT; size 14 mm; size 28 mm; size 8 mm; temperature 293 K to 298 K; Avalanche photodiodes; Breast; Computed tomography; Cooling; Crystals; Energy resolution; Position sensitive particle detectors; Positron emission tomography; Sensor arrays; Temperature sensors; PET/CT; breast imaging; dedicated; depth of interaction; high packing fraction;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
Conference_Location :
Honolulu, HI
ISSN :
1095-7863
Print_ISBN :
978-1-4244-0922-8
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2007.4436730
Filename :
4436730
Link To Document :
بازگشت