    DOI encoding on the PET detector using 2 × 2 PMT array

  • Author

    Inadama, Naoko ; Murayama, Hideo ; Yamaya, Taiga ; Nishikido, Fumihiko ; Shibuya, Kengo ; Yoshida, Eiji ; Lam, Chih Fung ; Takahashi, Kei ; Ohmura, Atsushi ; Ohi, Junichi

  • Author_Institution
    Nat. Inst. of Radiol. Sci., Chiba
  • Volume
    4
  • fYear
    2007
  • fDate
    Oct. 26 2007-Nov. 3 2007
  • Firstpage
    2968
  • Lastpage
    2971
  • Abstract
    We have begun to develop the PET detector which is composed of a scintillation crystal array and a 2times 2 array of inexpensive photomultiplier tubes (PMTs). The detector is intended for use for a low cost commercial whole body PET scanner. Anger type calculation of the four PMT outputs gives the 2-dimensional (2D) position histogram on which response of each crystal element appears and the scintillated crystal is identified on the histogram. The array of inexpensive PMTs however does not provide small sampling intervals like a position sensitive PMT and some crystal responses may overlap in the histogram due to insufficient scintillation light spread to the other three PMT outputs indirectly connected to the light-emitted crystals. To get more light spread and avoid the overlap of the responses, a light guide is generally inserted between the crystal array and the PMT array. We propose a new way to identify crystals which uses no light guides and which removes reflectors between some crystals and inserts some reflectors between the crystal array and the PMT array. The inserted reflector not only promotes light spread but also controls the light path to improve the crystal identification performance. Since the reflector is sufficiently thin, the method can be applied to a depth of interaction (DOI) detector with a new optical structure. By inserting a reflector between DOI crystal layers, it is possible to get a different light distribution between crystals in any DOI layer, which results in discrimination of all crystal responses in the 2D position histogram. We demonstrated the validity of this method and showed that it improved crystal identification ability without degradation of light output, and in turn, energy resolution. We also applied this method to a 2-layer DOI crystal array and verified its effect.
  • Keywords
    biomedical electronics; biomedical equipment; photomultipliers; positron emission tomography; solid scintillation detectors; DOI encoding; PET detector; PMT array; photomultiplier tubes; scintillation crystal array; two-dimensional position histogram; whole body PET scanner; Costs; Crystals; Encoding; Histograms; Optical arrays; Photomultipliers; Positron emission tomography; Sensor arrays; Solid scintillation detectors; Whole-body PET;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
  • Conference_Location
    Honolulu, HI
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-0922-8
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2007.4436757
  • Filename
    4436757