Reduced-scan schemes for X-ray fluorescence computed tomography
Author
La Rivière, Patrick J La ; Vargas, Phillip ; Newville, Matt ; Sutton, Stephen R.
Author_Institution
Univ. of Chicago, Chicago
Volume
4
fYear
2007
fDate
Oct. 26 2007-Nov. 3 2007
Firstpage
2991
Lastpage
2995
Abstract
X-ray fluorescence computed tomography (XFCT) is a synchrotron-based imaging modality employed for mapping the distribution of elements within slices or volumes of intact specimens. A pencil beam of external radiation is used to stimulate emission of characteristic X-rays from within a sample, which is scanned and rotated through the pencil beam in a first-generation tomographic geometry. The measurements so obtained can be represented as generalizations of the attenuated Radon Transform. The range of angular scanning employed is the subject of some variability in the XFCT imaging community, as some groups rotate the object through a full 360deg, while others employ only a 180deg rotation. In both cases, the entire object is scanned through the beam at each projection view. The use of a 180deg rotation is sometimes justified by implicit reference to a well-known symmetry property of the Radon transform, but that symmetry does not hold for the attenuated Radon transform. In this work, we demonstrate that a full scan of the object at each view coupled with a 360deg rotation does contain a two-fold data redundancy. While the redundancy does not give rise to a simple symmetry condition as in the case of the Radon transform, we will show that it does indeed license the use of 180deg scheme. However, we will also demonstrate that when there is a single external fluorescence detector, the redundancy also licenses a potentially more attractive reduced-scan scheme, in which the object is rotated through a full 360deg, but in which only the half of the object closest to the fluorescence detector is scanned at each projection view. This new scheme may permit both reduced imaging times and improved image quality.
Keywords
Radon transforms; computerised tomography; image reconstruction; medical image processing; Radon transform; X-ray fluorescence computed tomography; attenuation map; filtered backprojection reconstruction; sinogram; synchrotron-based imaging modality; two-fold data redundancy; Attenuation measurement; Computed tomography; Detectors; Fluorescence; Geometrical optics; Image quality; Licenses; Object detection; Optical imaging; X-ray imaging;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
Conference_Location
Honolulu, HI
ISSN
1095-7863
Print_ISBN
978-1-4244-0922-8
Electronic_ISBN
1095-7863
Type
conf
DOI
10.1109/NSSMIC.2007.4436763
Filename
4436763
Link To Document