Impact of respiratory motion on the detection of small pulmonary nodules in SPECT imaging
Author :
Smyczynski, M.S. ; Gifford, H.C. ; Lehovich, A. ; McNamara, J.E. ; Segars, W.P. ; Tsui, B.M.W. ; King, M.A.
Author_Institution :
Univ. of Massachusetts Med. Sch., Worcester
Volume :
5
fYear :
2007
fDate :
Oct. 26 2007-Nov. 3 2007
Firstpage :
3241
Lastpage :
3245
Abstract :
The objective of this investigation is to determine the impact of respiratory motion on the detection of small solitary pulmonary nodules (SPN) in single photon emission computed tomographic (SPECT) imaging. We have previously modeled the respiratory motion of SPN based on the change of location of anatomic structures within the lungs identified on breath-held CT images of volunteers acquired at two different stages of respiration. This information on respiratory motion within the lungs was combined with the end-expiration and time-averaged NCAT phantoms to allow the creation of source and attenuation maps for the normal background distribution of Tc-99m NeoTect. With the source and attenuation distribution thus defined, the SIMIND Monte Carlo program was used to produce SPECT projection data for the normal background and separately for each of 150 end-expiration and time-averaged simulated 1.0 cm tumors. Normal and tumor SPECT projection sets each containing one lesion were combined with a clinically realistic noise level and counts. These were reconstructed with RBI-EM using 1) no correction (NC), 2) attenuation correction (AC), 3) detector response correction (RC), and 4) attenuation correction, detector response correction, and scatter correction (ACRCSC). The post-reconstruction parameters of number of iterations and 3-D Gaussian filtering were optimized by human- observer studies. Comparison of lesion detection by human- observer LROC studies reveals that respiratory motion degrades tumor detection for all four reconstruction strategies, and that the magnitude of this effect is greatest for NC and RC, and least for AC RC SC. Additionally, the AC RC SC strategy results in the best detection of lesions.
Keywords :
Monte Carlo methods; cancer; filtering theory; image motion analysis; image reconstruction; lung; medical image processing; phantoms; pneumodynamics; single photon emission computed tomography; tumours; 3-D Gaussian filtering; SIMIND Monte Carlo program; anatomic structure location; attenuation correction; background distribution; breath-held CT images; clinically realistic noise level; detector response correction; end-expiration phantoms; human observer studies; image reconstruction; lesion detection; lung identification; respiratory motion; scatter correction; single photon emission computed tomographic imaging; small solitary pulmonary nodule detection; time-averaged NCAT phantoms; tumor SPECT projection set; Attenuation; Computed tomography; Detectors; Image reconstruction; Lesions; Lungs; Motion detection; Neoplasms; Optical computing; Single photon emission computed tomography;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
Conference_Location :
Honolulu, HI
ISSN :
1095-7863
Print_ISBN :
978-1-4244-0922-8
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2007.4436830
Filename :
4436830
Link To Document :
بازگشت