    Patient-specific noise-equivalent-counts from repeated, dose varying [O-15]H2O PET scans

  • Author

    Walker, Matthew D. ; Matthews, Julian C. ; Asselin, Marie-Claude ; Saleem, Azeem ; Price, Pat ; Jones, Terry

  • Author_Institution
    Univ. of Manchester, Manchester
  • Volume
    5
  • fYear
    2007
  • fDate
    Oct. 26 2007-Nov. 3 2007
  • Firstpage
    3277
  • Lastpage
    3282
  • Abstract
    Scanning protocols in dynamic PET imaging can be optimised to improve the accuracy and precision of measurements of physiological parameters. For [O-15]H2O scans, one of the major factors that can be controlled is the injected dose, which affects the statistical quality of the PET data as well as its accuracy. We build upon a previous dose optimisation methodology that considers patient-specific noise-equivalent-count-rates (NECRs), extending its use to dynamic PET scanning. The accuracy of this technique is examined within 4 individual patients. Each of these patients were given a series of between 4 and 6 injections of [O-15]H2O at doses that were intentionally varied between 140 and 740 MBq. Patient-specific NECR-dose curves were extrapolated from each injection. These data are used to qualify the performance of NECR-dose curve predictions in a dynamic PET setting, as found on a modern LSO PET/CT scanner. The optimal dose was defined as the dose required to give 95 % maximisation of the integral NEC within a specified time interval post administration. We find good agreement between the extrapolated NECR curves within an individual. On average, the variability between injections produced a standard deviation of 3 % in the optimal dose calculated for the specific patient. The optimal doses ranged from 264 to 640 MBq between subjects, for maximising the NECR during the times most critical to the measurement of blood flow. We also find that although administration of the tracer at the back of the wrist in a pelvic scan produces a higher global NECR, the signal-to-noise ratio in the image is reduced compared to a similar injected dose at the elbow. We conclude that patient-specific NECR methods can provide useful guidance in dose optimisation.
  • Keywords
    dosimetry; haemodynamics; noise; optimisation; positron emission tomography; NECR-dose curve; blood flow; dose optimisation methodology; dynamic positron emission tomography; patient-specific noise-equivalent-counts; signal-noise ratio; volume-of-distribution; Blood flow; Computed tomography; Elbow; Fluid flow measurement; National electric code; Optimization methods; Positron emission tomography; Protocols; Signal to noise ratio; Wrist; Dynamic positron emission tomography; NEC; PET; blood flow; dose optimisation; injected dose; noise equivalent count rate; volume-of-distribution; water;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
  • Conference_Location
    Honolulu, HI
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-0922-8
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2007.4436837
  • Filename
    4436837