A small gamma camera combined with a uniformly redundant array (URA) collimator: the performance evaluation using detective quantum efficiency (DQE)
Author :
Jeon, Hosang ; Kim, Hyunduk ; Lee, Chae Hun ; Chang, Sungho ; Rahman, Mohammad S. ; Cho, Gyuseong
Author_Institution :
Korea Adv. Inst. of Sci. & Technol., Daejeon
Volume :
2
fYear :
2007
fDate :
Oct. 26 2007-Nov. 3 2007
Firstpage :
1237
Lastpage :
1240
Abstract :
The gamma scintillation camera systems are recently used in various industrial, environmental and medical diagnostic fields. Moreover, the portable use in various fields is possible using miniaturized gamma camera systems. The necessity of objective and quantitative factors for the performance evaluation of gamma camera systems increase as the usefulness of these systems increase. The detective quantum efficiency(DQE), which is already applied to the performance evaluation of X-ray imaging systems, was partially revised and applied to our gamma camera system. In this study, our gamma camera system consisted of a scintillation crystal, a PSPMT with 5-inch diameter and read-out electronics. The four collimators, three pinhole collimators with different pinhole diameters and a coded-aperture collimator using uniformly redundant array (URA), were manufactured for imaging experiments. In the result, the spatial resolution slightly decrease as pinhole diameter increase because of thick scintillation material for high energy photons detection. The normalized noise power spectra obviously decrease as pinhole diameter increase because of signal to noise ratio. Finally, the DQE increase as pinhole diameter increase. The highest DQE was presented by the URA collimator. In spite of slightly low spatial resolution, URA present highest performance because of very low noise power. Our results present interrelation with conventional evaluating factors, for example, FWHM and uniformity. We found that DQE can be effectively used to evaluate imaging performance of gamma camera systems.
Keywords :
X-ray imaging; cameras; collimators; gamma-ray detection; nuclear electronics; performance evaluation; photomultipliers; position sensitive particle detectors; readout electronics; solid scintillation detectors; PSPMT; X-ray imaging systems; coded-aperture collimator; detective quantum efficiency; environmental fields; gamma scintillation camera systems; high energy photon detection; industrial fields; medical diagnostic fields; normalized noise power spectra; performance evaluation; pinhole collimators; read-out electronics; signal-noise ratio; size 5 inch; spatial resolution; uniformly redundant array collimator; Cameras; Collimators; Gamma ray detection; Gamma ray detectors; High-resolution imaging; Medical diagnosis; Optical imaging; Signal to noise ratio; Solid scintillation detectors; Spatial resolution;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
Conference_Location :
Honolulu, HI
ISSN :
1095-7863
Print_ISBN :
978-1-4244-0922-8
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2007.4437228
Filename :
4437228
Link To Document :
بازگشت