• DocumentCode
    469989
  • Title

    A PET prototype for in-beam monitoring of proton therapy

  • Author

    Vecchio, Sara ; Attanasi, Francesca ; Belcari, Nicola ; Camarda, Manuela ; Cirrone, G. A Pablo ; Cuttone, Giacomo ; Guerra, Alberto Del ; Rosa, Francesco Di ; Lanconelli, Nico ; Moehrs, Sascha ; Rosso, Valeria ; Russo, Giorgio

  • Author_Institution
    Univ. of Pisa, Pisa
  • Volume
    2
  • fYear
    2007
  • fDate
    Oct. 26 2007-Nov. 3 2007
  • Firstpage
    1607
  • Lastpage
    1611
  • Abstract
    The in-beam PET is a novel PET application to image the beta+ activity induced in biological tissues by hadronic therapeutic beams. Thanks to the correlation existing between beam-delivered dose profiles and beam-induced activity profiles, in vivo information about the effective ion paths can be extracted from the in-beam PET image. In-situ measurements, immediately after patient irradiation, are recommended in order to exploit the maximum statistics, by detecting the contribution provided by short lived isotopes. A compact, dedicated tomograph should then be developed for such an application, so as to be used in the treatment room. We have realized a small PET prototype in order to demonstrate the feasibility of such technique for the monitoring of proton therapy of ocular tumors at the CATANA facility (Catania, Italy). The DoPET (dosimetry with a positron emission Tomograph) tomograph consists of two planar heads, with an active area of about 5 cm x 5 cm. Each head is made up of a squared position sensitive photomultiplier (Hamamatsu H8500) coupled to a matrix of the same size of LYSO scintillating crystals (2 mm times 2 mm times 18 mm pixel dimensions). Dedicated, compact electronic boards are used for the signal multiplexing, amplification and digitization. The distance between the pair can be set from 10 cm up to a maximum of about 20 cm. The validation of the prototype was performed using 62 MeV protons at the CATANA beam line and plastic phantoms. Different dose distributions have been delivered and a good correlation between the distal fall-off of the activity profiles and of the dose profiles was found, i.e., better than 2 mm along the beam direction.
  • Keywords
    amplification; dosimetry; multiplexing; patient diagnosis; phantoms; photomultipliers; positron emission tomography; radiation monitoring; radiation therapy; tumours; CATANA beam line; CATANA facility; DoPET; Dosimetry with a Positron Emission Tomograph; amplification; beam-delivered dose profiles; beam-induced activity profiles; biological tissues; digitization; dose distributions; dose profiles; electron volt energy 62 MeV; hadronic therapeutic beams; in-beam monitoring; ocular tumors; patient irradiation; plastic phantoms; proton therapy monitoring; scintillating crystals; signal multiplexing; squared position sensitive photomultiplier; Biological tissues; Data mining; Head; In vivo; Medical treatment; Monitoring; Positron emission tomography; Protons; Prototypes; Statistics;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
  • Conference_Location
    Honolulu, HI
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-0922-8
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2007.4437306
  • Filename
    4437306