DocumentCode :
47127
Title :
K-factor value of SF6 gas gap under non-homogeneous electric field for UHV-class gas-insulated switchgear
Author :
Tsuboi, Toshihiro ; Ueta, Genyo ; Okabe, Shigemitsu ; Shimizu, Yukiyo ; Inami, K.
Author_Institution :
R&D Center, Tokyo Electr. Power Co., Yokohama, Japan
Volume :
21
Issue :
3
fYear :
2014
fDate :
Jun-14
Firstpage :
988
Lastpage :
994
Abstract :
The lightning impulse voltage test waveform of power equipment is prescribed in the IEC 60060-1 "High-voltage test techniques" revised in 2010. This revision introduced an evaluation method by k-factor function (test voltage function), which converts an overshoot waveform to a test voltage waveform. At present, the test standard for UHV-class equipment is being studied and the authors have experimentally acquired k-factor values for gas-insulated switchgears, oil-immersed transformers and air insulation using the largest possible model assuming an actual UHV-class equipment to date. This paper reports the experimental result on the breakdown characteristics of lightning impulse voltage test waveforms for the SF6 gas insulation model under a nonhomogeneous electric field. The k-factor value was calculated by measuring the breakdown voltage and time using the superimposed oscillation frequency and the overshoot rate as parameters. The change with respect to the superimposed frequency of this experiment was similar to that of the existing k-factor function, and the effectiveness of evaluation by the k-factor function was confirmed.
Keywords :
SF6 insulation; electric breakdown; gas insulated switchgear; high-voltage techniques; inhomogeneous media; switchgear testing; IEC 60060-1; SF6 gas insulation model; UHV-class equipment; air insulation; breakdown characteristics; breakdown voltage; gas-insulated switchgears; high-voltage test techniques; k-factor function; k-factor values; lightning impulse voltage test waveform; nonhomogeneous electric field; oil-immersed transformers; overshoot rate; overshoot waveform; power equipment; superimposed oscillation frequency; test voltage function; test voltage waveform; Breakdown voltage; Electric breakdown; Electric fields; Lightning; Oscillators; Standards; Sulfur hexafluoride; IEC 60060-1; Lightning impulse voltage test; SF6 gas gap; gasinsulated switchgear; k-factor; non-homogeneous electric field; ultra high voltage;
fLanguage :
English
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
1070-9878
Type :
jour
DOI :
10.1109/TDEI.2014.6832241
Filename :
6832241