Abstract :
Studies examining traumatic brain injury have suggested a ´window of opportunity´ exists for therapeutic agents to mitigate edema and cellular toxicity effectively. However, successful therapy also relies on identifying the extent of blood-brain barrier disruption, which is associated with excessive extra-cellular concentrations of ions, excitatory amino acids, and serum proteins. The following study investigates the use of pH-selective hydrous iridium oxide microelectrodes to assess trauma following insertion of a neural probe. Electrochemical activation of iridium microelectrode arrays was performed in either acidic (0.5 M H2SO4) or weak basic (0.3 M Na2HPO4, pH=8.56) solutions. Both oxides demonstrated super-Nernstian pH sensitivity (-88.5 mV/pH and -77.1 mV/pH, respectively) with little interference by other cations. Data suggest that acid-grown oxide provides better potential stability than base-grown oxide (sigma=2.8 versus 4.9 mV over 5 hours). Implantation of these electrodes into motor cortex and dorsal striatum revealed significant acidosis during and following insertion. Variability in the spatiotemporal pH profile included micro-scale inhomogeneities along the probe shank and significant differences in the averaged pH response between successive insertions using the same depth and speed. This diagnostic technology has important implications for intervention therapies in order to more effectively treat acute surgical brain trauma
Keywords :
biochemistry; bioelectric potentials; biomedical electrodes; brain; cellular biophysics; electrochemical electrodes; iridium compounds; microelectrodes; molecular biophysics; neurophysiology; pH; patient diagnosis; proteins; spatiotemporal phenomena; IrO; acid-grown oxide; base-grown oxide; blood-brain barrier disruption; cellular toxicity; dorsal striatum; electrochemical activation; electrodiagnostic technology; excitatory amino acids; extra-cellular concentrations; micro-scale inhomogeneities; motor cortex; neural interface dynamics; neural probe insertion; pH-selective hydrous iridium oxide microelectrode array; serum proteins; spatiotemporal pH profile; super-Nernstian pH sensitivity; traumatic brain injury; Amino acids; Brain injuries; Electrodes; Interference; Medical treatment; Microelectrodes; Probes; Proteins; Spatiotemporal phenomena; Stability;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2006. EMBS '06. 28th Annual International Conference of the IEEE
Conference_Location :
New York, NY
ISSN :
1557-170X
Print_ISBN :
1-4244-0032-5
Electronic_ISBN :
1557-170X
Type :
conf
DOI :
10.1109/IEMBS.2006.260521
Filename :
4462472
Link To Document :
بازگشت