DocumentCode :
472274
Title :
Development of the human interface equipment based on surface EMG employing channel selection method
Author :
Nagata, Kentaro ; Ando, Keiichi ; NAKANO, Shinji ; NAKAJIMA, Hideaki ; Yamada, Masafumi ; Magatani, Kazushige
Author_Institution :
Dept. of Electr. & Electron. Eng., Tokai Univ., Kanagawa
fYear :
2006
fDate :
Aug. 30 2006-Sept. 3 2006
Firstpage :
6193
Lastpage :
6196
Abstract :
In this paper, we describe the human-interface equipment using surface electromyogram (SEMG) based on optimal measurement channels for each subject. In case the SEMG is used as a control signal, individual differences of SEMG are important issue to obtain high accuracy recognition of motions. To solve this problem, we propose a channel selection method of the suitable measurement channels for the recognition of motions. We use a 96-channel matrix-type (6times16) surface electrode attached to the forearm in order to measure the SEMG generated from many active muscles during hand motions. From those 96 electrodes, our system decided the number of measurement channels and the position of measurement channels. This can be achieved by using the Monte Carlo method. Our system generates 10,000 sets of randomly selected channels, and these sets are evaluated by the recognition rate of hand motions. One set that records a highest recognition rate is selected from 10,000 sets for an optimal set of measurement channels. And the one set with the smallest number of measurement channels which fulfil the recognition rate above 90% or the maximum recognition rate above 95% is used for real-time recognition. Six normal subjects were experimentally tested using our system. The recognition rates of 18 hand motions, including 10 finger movements, were assessed for every subject. We were able to distinguish all the motions, and the average recognition rate in the real-time experiment was measured to be greater than 95%. And the number of selected channels ranged from 4 to 7
Keywords :
Monte Carlo methods; biomechanics; biomedical electrodes; biomedical measurement; electromyography; medical computing; real-time systems; user interfaces; Monte Carlo method; active muscles; channel selection method; finger movements; hand motion recognition rate; human interface equipment; optimal measurement channels; real-time experiment; surface electrode; surface electromyogram; Cities and towns; Control systems; Electric variables measurement; Electrodes; Electromyography; Humans; Motion measurement; Muscles; Position measurement; USA Councils;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2006. EMBS '06. 28th Annual International Conference of the IEEE
Conference_Location :
New York, NY
ISSN :
1557-170X
Print_ISBN :
1-4244-0032-5
Electronic_ISBN :
1557-170X
Type :
conf
DOI :
10.1109/IEMBS.2006.260783
Filename :
4463223
Link To Document :
بازگشت