DocumentCode
473257
Title
Fast Fault Detection and Location of a Zonal Marine Power System: Using Active Impedance Estimation
Author
Wang, Jiacheng ; Thomas, David W. P. ; Sumner, M. ; Geertsma, R.D.
Author_Institution
Sch. of Electical & Electron. Eng., Univ. of Nottingham, Nottingham
fYear
2008
fDate
17-20 March 2008
Firstpage
490
Lastpage
494
Abstract
On marine distribution systems traditional protection schemes often fail to provide the necessary reliability and discrimination. In this paper, a novel protection scheme for a zonal system, as proposed for marine applications, is presented based on active impedance estimation. The power system impedance is measured by injecting a very short current transient onto the network via a coupling inductance and analysing the transient response to this using the measured voltages and currents. Wavelet analysis is used in the data processing to estimate the system impedance over a broad frequency range; the identified impedance can be used for fault discrimination. The speed, accuracy and range of validity of such an approach are fully explored. It is shown that this scheme provides a useful compliment to traditional protection strategies and can also provide the necessary back up protection during extreme protection failure.
Keywords
fault location; power system protection; transient response; active impedance estimation; data processing; fast fault detection; fast fault location; fault discrimination; marine distribution systems traditional protection schemes; power system impedance; transient response; zonal marine power system; Circuit faults; Current measurement; Impedance; Power system transients; Power systems; Transient analysis; Voltage measurement;
fLanguage
English
Publisher
iet
Conference_Titel
Developments in Power System Protection, 2008. DPSP 2008. IET 9th International Conference on
Conference_Location
Glasgow
ISSN
0537-9989
Print_ISBN
978-0-86341-902-7
Type
conf
Filename
4497034
Link To Document