DocumentCode
47347
Title
Model-Based Correction of Velocity Measurements in Navigated 3-D Ultrasound Imaging During Neurosurgical Interventions
Author
Iversen, Daniel Hoyer ; Lindseth, Frank ; Unsgaard, Geirmund ; Torp, Hans ; Lovstakken, Lasse
Author_Institution
Dept. of Circulation & Med. Imaging, Norwegian Univ. of Sci. & Technol., Trondheim, Norway
Volume
32
Issue
9
fYear
2013
fDate
Sept. 2013
Firstpage
1622
Lastpage
1631
Abstract
In neurosurgery, information of blood flow is important to identify and avoid damage to important vessels. Three-dimensional intraoperative ultrasound color-Doppler imaging has proven useful in this respect. However, due to Doppler angle-dependencies and the complexity of the vascular architecture, clinical valuable 3-D information of flow direction and velocity is currently not available. In this work, we aim to correct for angle-dependencies in 3-D flow images based on a geometric model of the neurovascular tree generated on-the-fly from free-hand 2-D imaging and an accurate position sensor system. The 3-D vessel model acts as a priori information of vessel orientation used to angle-correct the Doppler measurements, as well as provide an estimate of the average flow direction. Based on the flow direction we were also able to do aliasing correction to approximately double the measurable velocity range. In vitro experiments revealed a high accuracy and robustness for estimating the mean direction of flow. Accurate angle-correction of axial velocities were possible given a sufficient beam-to-flow angle for at least parts of a vessel segment . In vitro experiments showed an absolute relative bias of 9.5% for a challenging low-flow scenario. The method also showed promising results in vivo, improving the depiction of flow in the distal branches of intracranial aneurysms and the feeding arteries of an arteriovenous malformation. Careful inspection by an experienced surgeon confirmed the correct flow direction for all in vivo examples.
Keywords
Doppler measurement; biomedical ultrasonics; blood flow measurement; blood vessels; neurophysiology; physiological models; surgery; velocity measurement; 3-D flow image; 3-D ultrasound imaging; Doppler angle-dependency; Doppler measurement; a priori information; arteriovenous malformation; average flow direction; axial velocity; beam-to-flow angle; blood flow information; blood vessel; distal branches; feeding artery; free-hand 2-D imaging; geometric model; intracranial aneurysm; model-based correction; neurosurgery; neurosurgical intervention; neurovascular tree; on-the-fly; position sensor system; three-dimensional intraoperative ultrasound color-Doppler imaging; vascular architecture; velocity measurement; vessel orientation; vessel segment; Blood; Imaging; In vitro; Navigation; Solid modeling; Ultrasonic imaging; Velocity measurement; Blood vessels; brain; ultrasound; velocity estimation; Blood Flow Velocity; Brain; Cerebrovascular Circulation; Echoencephalography; Humans; Imaging, Three-Dimensional; Intracranial Aneurysm; Intracranial Arteriovenous Malformations; Neurosurgical Procedures; Reproducibility of Results;
fLanguage
English
Journal_Title
Medical Imaging, IEEE Transactions on
Publisher
ieee
ISSN
0278-0062
Type
jour
DOI
10.1109/TMI.2013.2261536